时间:2021-05-19
新接手了一台Linux服务器,准备检查是否有配置RAID。
先查看是否有RAID卡:
复制代码 代码如下:
# dmesg|grep -i raid
mptsas: ioc0: attaching raid volume, channel 1, id 0
device-mapper: dm-raid45: initialized v0.2594l
md: Autodetecting RAID arrays.
很明显是有的,只是无法确定RAID卡的类型是ioc0还是dm-raid45,于是开始百度。后来找到了这样一个工具:mpt-status,而且在下载界面里,有这样几句话:
mpt-status: get status of LSI 1030 RAID (mptlinux, fusion, mpt, ioc) controller
This driver has many names. As best I understand their use:
LSI 1030
The make and model of the controller
mptlinux
The name of the driver distribution. /proc/mpt/version might say, for example, mptlinux-2.05.11.03.
Fusion
The trade name for the chipset (?). The driver distribution, though called mptlinux, actually lives in drivers/message/fusion.
mpt
Message Passing Technology; the prefix used for all things that related to the driver. The /proc device is /proc/mptctl, for example.
ioc
The name of the controller within Linux. For example the first controller is ioc0.
大意是说LSI 1030 RAID卡有很多个名字,ioc是其中之一。这刚好与之前dmesg的结果吻合。因此基本上可以确定RAID卡的类型是ioc0,属于LSI的产品,可以用mpt-status来对其进行监控。
mpt-status下载地址:http://sven.stormbind.net/mpt-status-rhel/
接着下载安装:rpm -ihv mpt-status-1.2.0_RC7-3.i386.rpm
建立字符设备:mknod /dev/mptctl c 10 220
加载内核模块mptctl:modprobe mptctl
查看RAID状态:
复制代码 代码如下:
# mpt-status
ioc0 vol_id 0 type IM, 2 phy, 465 GB, state OPTIMAL, flags ENABLED
ioc0 phy 1 scsi_id 8 ATA WDC WD5002ABYS-1 3B04, 465 GB, state ONLINE, flags NONE
ioc0 phy 0 scsi_id 1 ATA WDC WD5002ABYS-1 3B04, 465 GB, state ONLINE, flags NONE
可以看出,该RAID由两块465G的物理硬盘组成,状态良好。可问题是,RAID级别是多少(0,1,5...)呢?
于是接着百度。
但这次没有结果。
后来在mpt-status的文档(/usr/share/doc/mpt-status-1.2.0_RC7/FAQ )里看到这样一句话:
> 1) Could you tell me from example #1, #2 and #3 where can you see the Raid Level of each hard disk ?
好激动,这不就是我要问的问题吗?再看看答案:
The raid level is not visible, would you like to get this information as well? Or do you want to extract the health state of each disk?
尼玛,回答跟没回答一样...
接着往下看。终于,在文档的最后,给出来了答案:
> IS=?
Integrated Striping (RAID 0)
> IM=?
Integrated Mirroring (RAID 1)
即mpt-status输出的type表示RAID级别。如上例中的:
ioc0 vol_id 0 type IM, 2 phy, 465 GB, state OPTIMAL, flags ENABLED
表示RAID1。
最后附上mpt-status的rpm包。
mpt-status 下载地址:http://sven.stormbind.net/mpt-status-rhel/
声明:本页内容来源网络,仅供用户参考;我单位不保证亦不表示资料全面及准确无误,也不保证亦不表示这些资料为最新信息,如因任何原因,本网内容或者用户因倚赖本网内容造成任何损失或损害,我单位将不会负任何法律责任。如涉及版权问题,请提交至online#300.cn邮箱联系删除。
raid卡也许大家都没什么概念,到底什么是raid卡呢?raid也称为磁盘阵列。Raid就是把多个独立的物理硬盘根据不同的方式,排列组合成一个硬盘组也就是逻辑硬
1、Nginx状态监控Nginx提供了一个内置的状态信息监控页面可用于监控Nginx的整体访问情况,这个功能由ngx_http_stub_status_modu
本文讲述了LINUX下Oracle数据导入导出的方法。分享给大家供大家参考,具体如下:一.导出工具exp1.它是操作系统下一个可执行的文件存放目录/ORACLE
在终端上工作时,通常会发现终端屏幕上显示了太多的命令及其输出。你可能需要清除终端屏幕并专注于要执行的下一个任务。相信我,清除Linux终端屏幕会很有帮助。使用c
linux下一个网卡如何配置多个IP?linux下边如果没有图形界面了配置网络还真的不是太方便了,呵呵,习惯问题,当然习惯需要改的,最近遇到一个问题需要单网卡配