时间:2021-05-24
ERRNO: 256
TEXT: SQLSTATE[HY000]: General error: 1436 Thread stack overrun: 4904 bytes used of a 131072 byte stack, and 128000 bytes needed. Use 'mysqld -O thread_stack=#' to specify a bigger stack.
According to the MySQL manual “The default (192KB) is large enough for normal operation. If the thread stack size is too small, it limits the complexity of the SQL statements that the server can handle, the recursion depth of stored procedures, and other memory-consuming actions” .
To resolve this issue you need to change the default value of parameter 'thread_stack' in /etc/my.cnf in your MySQL configuration file.I use the XAMPP for php/mysql development.
Once you set this value you need to restart MySQL as this value cannot be set dynamically.
you maybe also encounter with the message when you try to modify the my.cnf
"Cannot open file for writing: Permission denied"
We will try to use the 'chmod' instruction to change permission as usually. I seldom take the concrete permission into consideration, so I use always use the 'chmod 777'. but it resulted in another errors when I use the phpmyadmin, another tools included in XAMPP, after running 'chmod 777'.
After googling it, I get this file (my.cnf) permissions has to be 600. I change its permission and it works well now.
bug info
报错信息:
java.sql.SQLException: Thread stack overrun: 5456 bytes used of a 131072 byte stack, and 128000 bytes needed. Use 'mysqld --thread_stack=#' to specify a bigger stack.
官方相应信息:
The default (192KB) is large enough for normal operation. If the thread stack size is too small, it limits the complexity of the SQL statements that the server can handle, the recursion depth of stored procedures, and other memory-consuming actions
可以使用
show variables where `variable_name` = 'thread_stack';
查询当前数据库的默认线程栈的大小,一般情况下都能正常使用,但是当查询语句或者存储过程复杂时会报Thread stack overrun错误,此时只要修改默认配置就可以。
解决
windows: 修改mysql安装目录下的my-small.ini或者my.ini设置为256k,或者更大,然后重启服务
[mysqld]
thread_stack = 256k
linux: 同样要修改配置文件,但是!!!,不是安装目录下的配置文件,是/etc/my.cnf,只有这个文件才能生效,然后重启服务service mysql restart
[mysqld]
thread_stack = 256k
其实针对32位系统,32G内存,一般设置为512K即可,据国外网站看到的,如果是64位的系统可以适当增加,其实够用就好了,没必须刚开始设置的就很大。
声明:本页内容来源网络,仅供用户参考;我单位不保证亦不表示资料全面及准确无误,也不保证亦不表示这些资料为最新信息,如因任何原因,本网内容或者用户因倚赖本网内容造成任何损失或损害,我单位将不会负任何法律责任。如涉及版权问题,请提交至online#300.cn邮箱联系删除。
缘起:[root@CentOS7code]#pythonmulti_thread_mfw.pyFile"multi_thread_mfw.py",line138
fromhttp:///c/a/MySQL/Error-Handling-Examples/ErrorHandlerExamplesHerearesomeexa
1.启动MySQL时一直不成功,查看错误日志/var/log/mysql/error.log2.主要的错误信息有如下几条:[ERROR]InnoDB:mmap(
问题mysql查询出现错误error:(2014,"Commandsoutofsync;youcan'trunthiscommandnow")1查询mysql文
ERROR1130(HY000):Host'localhost'isnotallowedtoconnecttothisMySQLserver出现原因:mysql